JS Type Square Negative Pressure Exhaust Fan
JS type square negative pressure exhaust fan adopts heavy-duty square frame design, featuring large air volume, fast air exchange and low noise. Heat dissipation, smoke exhaust, dust removal and cooling integrated. Easy installation, stable running, ideal for factory, poultry farm, warehouse and greenhouse ventilation.
Product Overview
The JS Type Square Negative Pressure Exhaust Fan is a high-efficiency industrial ventilation fan designed for factory cooling, air exchange, and large-scale exhaust applications. Featuring a square box structure with carbon steel blades, the fan provides large airflow, low power consumption, long-distance air delivery, and low-noise operation.
The product is widely used in industrial plants, warehouses, greenhouses, poultry farms, livestock buildings, and commercial ventilation systems.
Available configurations include:
Direct Drive Type (A Type)
Belt Drive Type (C Type)
Louver Type
Front-and-Back Protective Net Type
Product Features
- Large Airflow & Energy Saving Equipped with 6 carbon steel blades to deliver powerful airflow while maintaining low energy consumption.
- Low Noise Operation Optimized blade structure and airflow design reduce operational noise, making the fan suitable for continuous industrial ventilation.
- Multiple Drive Configurations
- Different drive methods satisfy various ventilation and installation requirements.
- Automatic Louver System Louver type models automatically open and close during operation, preventing rainwater, dust, and reverse airflow.
- Safety Protection Design Front-and-back protective net models improve operational safety and prevent foreign object intrusion.
- Durable Construction Heavy-duty iron housing combined with carbon steel impeller ensures long-term stable operation.
Applications
- Industrial factories
- Manufacturing workshops
- Warehouses
- Office buildings
- Greenhouses
- Poultry farms
- Livestock breeding facilities
- Cooling and ventilation systems
- Industrial exhaust and air circulation systems
Working Conditions
- Conveyed medium: Non-flammable and low-corrosive gas
- Gas temperature: ≤ 50°C
- Relative humidity: ≤ 80%
- Dust and solid impurities:
- ≤ 100 mg/m³
- English standard version: ≤ 150 mg/m³
Certifications
- CE Certification
- SASO Certification
- CB Certification
- GCC Certification
- CCC Certification
Product Structure
- A Type – Direct Drive Motor directly drives the impeller for stable operation, lower maintenance, and higher transmission efficiency.
- C Type – Belt DriveBelt transmission design allows flexible operation and easier maintenance for various working conditions.
- Louver ConfigurationAutomatic shutter system prevents reverse airflow and protects the internal structure.
- Protective Net ConfigurationFront-and-back protective nets improve safety during operation.
Main Technical Parameters
JS-II A Type (Direct Drive)
| Model | Power (kW) | Voltage (V) | Speed (r/min) | Air Volume (m³/h) | Noise dB(A) | Configuration |
| JS-II-4A | 0.37 | 220/380 | 1400 | 7200 | ≤73 | With Louver |
| JS-II-5A | 0.55 | 220/380 | 1400 | 8600 | ≤75 | With Louver |
| JS-II-6A | 0.25 | 220/380 | 720 | 17000 | ≤70 | Louver / Protective Net |
| JS-II-8A | 0.4 | 220/380 | 520 | 23000 | ≤71 | Louver / Protective Net |
| JS-II-9A | 0.55 | 220/380 | 520 | 27500 | ≤73 | Louver / Protective Net |
| JS-II-10A | 0.55 | 380 | 460 | 32000 | ≤74 | Louver / Protective Net |
| JS-II-12A | 0.75 | 380 | 460 | 37000 | ≤75 | Louver / Protective Net |
| JS-II-13A | 1.1 | 380 | 460 | 44500 | ≤78 | Louver / Protective Net |
JS-II C Type (Belt Drive)
| Model | Power (kW) | Voltage (V) | Speed (r/min) | Air Volume (m³/h) | Noise dB(A) | Configuration |
| JS-II-8C | 0.55 | 220/380 | 520 | 23000 | ≤71 | Louver / Protective Net |
| JS-II-9C | 0.75 | 220/380 | 520 | 27500 | ≤73 | Louver / Protective Net |
| JS-II-10C | 0.75 | 220/380 | 460 | 32000 | ≤74 | Louver / Protective Net |
| JS-II-12C | 1.1 | 220/380 | 460 | 37000 | ≤75 | Louver / Protective Net |
| JS-II-13C | 1.1 | 220/380 | 460 | 44500 | ≤78 | Louver / Protective Net |
Installation Dimensions
A Type with Louver
| Model | L (mm) | B (mm) | H (mm) | Impeller Diameter Φ(mm) | Bolt Specification |
| 4A | 502 | 342 | 502 | 395 | — |
| 5A | 602 | 342 | 602 | 495 | — |
| 6A | 752 | 332 | 750 | 580 | 8-M8 |
| 8A | 982 | 372 | 980 | 780 | 8-M8 |
| 9A | 1052 | 372 | 1050 | 880 | 8-M8 |
| 10A | 1112 | 372 | 1050 | 965 | 8-M8 |
| 12A | 1222 | 402 | 1220 | 1040 | 8-M8 |
| 13A | 1383 | 402 | 1381 | 1220 | 8-M8 |
Product Advantages
- High Airflow Performance Large airflow volume with long-distance air delivery for factory ventilation and cooling applications.
- Energy Efficient Low power consumption reduces operational costs for long-term industrial use.
- Quiet Operation Noise levels controlled within ≤70–78 dB(A), suitable for noise-sensitive environments.
- Flexible Installation Multiple protection and drive configurations adapt to different installation requirements.
- Reliable & Durable Iron housing and carbon steel blades ensure stable and long-lasting performance.
- Safety Protection Automatic louvers and protective net options improve operational safety.
OEM & ODM Services
- OEM manufacturing
- ODM customization
- Customized voltage and frequency
- Customized protective configurations
- Customized dimensions and appearance
- Private label packaging support
Related products
-
Axial Fans
DPT Series Large Air Volume Silent Fan
-
Axial Fans
EG Series Energy-Saving Duct Fan
-
Axial Fans
SF(B) Wall-Mounted Axial Flow Fan